Technical stuff.
Each stove is constructed from high grade steel tubing, curved to form the cylindrical fire box. As most of the steel tube is within the burn chamber the heat from the fire warms the air rapidly. As the warmed air rises it draws cool air in beneath and so the cycle continues. The pipes and the claddings both help to give direction to the air flow encouraging the efficient convection.
Technical Specification.
Bullerjan Type |
Unit |
00 |
01 |
02 |
03 |
04 NZ |
05 NZ |
Rated Thermal Output (RTO) |
kW |
6 |
11 |
14 |
20 |
35 |
45 |
Maximum quantity of combustibles |
kg/hr |
2 |
4 |
5 |
7 |
12 |
15 |
Waste Gas Mass Flow Rate relating to RTO |
g/s |
9.2 |
17.3 |
14.5 |
* |
* |
* |
Mean/Max Waste Gas temperature |
o C |
262/325 |
304/354 |
335/377 |
* |
* |
* |
Delivery pressure |
mbar |
0.10 |
0.11 |
0.11 |
* |
* |
* |
Delivery Pressure at 0.8 x RTO |
mbar |
0.08 |
0.09 |
0.09 |
* |
* |
* |
CO 2 |
% |
6.5 |
6.7 |
9.1 |
* |
* |
* |
Efficiency |
% |
70.3 |
70.5 |
70.6 |
* |
* |
* |
Sufficient to Heat |
M 3
Ft 3
|
100
3,531 |
200
7,062 |
400
14,124 |
600
21,186 |
1,000
35,310
|
1,300
45,903 |
* Information not currently available .
**Detail may be changed without notice
Technical Data.
Bullerjan Type
|
Unit |
00 |
01 |
02 |
03 |
04 NZ |
05 NZ |
Depth |
cm |
62 |
71 |
85 |
114 |
140 |
153 |
Width |
cm |
53 |
63 |
67 |
67 |
80 |
88 |
Height |
cm |
65 |
68 |
81 |
81 |
90 |
94 |
Weight |
kg |
69 |
83 |
117 |
187 |
261 |
335 |
Length of Combustion Chamber |
cm |
40 |
50 |
60 |
60 |
75 |
80 |
Door Diameter |
cm |
27 |
27 |
31 |
31 |
35 |
38 |
Exhaust Flue Diameter |
cm |
12 |
12 |
15 |
15 |
16 |
18 |
Approx height to centre of exhaust flue |
cm |
48 |
51 |
62 |
62 |
72 |
72 |
Number of pipes |
|
7 |
7 |
9 |
13 |
16 |
17 |
**Detail may be changed without notice |